[1]勒都晓兰,吕发金,陈莉,等.ESWAN序列参数对不同浓度FeSO4溶液成像效果的研究[J].第三军医大学学报,2012,34(18):1901-1904.
 Ledu Xiaolan,Lu Fajin,Chen Li,et al.Imaging of FeSO4 solution at different concentrations by ESWAN sequence with different parameters[J].J Third Mil Med Univ,2012,34(18):1901-1904.
点击复制

ESWAN序列参数对不同浓度FeSO4溶液成像效果的研究(/HTML )
分享到:

《第三军医大学学报》[ISSN:1000-5404/CN:51-1095/R]

卷:
34卷
期数:
2012年第18期
页码:
1901-1904
栏目:
论著
出版日期:
2012-09-30

文章信息/Info

Title:
Imaging of FeSO4 solution at different concentrations by ESWAN sequence with different parameters
作者:
勒都晓兰吕发金陈莉姚开情李剑秋
重庆医科大学附属第一医院放射科
Author(s):
Ledu Xiaolan Lu Fajin Chen Li Yao Kaiqing Li Jianqiu
Department of Radiology, First Affiliated Hospital, Chongqing Medical University, Chongqing, 400016, China
关键词:
磁共振成像增强梯度回波T*2加权血管成像相位参数
Keywords:
magnetic resonance imaging enhanced gradient echo T2* weighted angiography phase parameters
分类号:
R445.2;R811
文献标志码:
A
摘要:
目的      采用体外实验方法研究增强梯度回波T2*加权血管成像(enhanced gradient echo T2 star weighted angiography, ESWAN)序列不同参数设置对不同浓度顺磁性离子(Fe2+)的成像效果的影响。      方法      建立1个不同浓度FeSO4溶液模型,在ESWAN序列上使用不同的回波数、翻转角(flip angle,FA)、带宽(bandwidth,BW)、视野(field of view, FOV)对样本进行重复扫描,观察信号的变化。通过测量样本各层面图像感兴趣区的相位值,分析成像结果与不同参数之间的关系。      结果      ESWAN显示Fe2+呈稍高信号。当Fe2+浓度≤0.01 mmol/L时,相位值随浓度增高而增高。当浓度为0.1 mmol/L时,伪影增多,相位值降低。在不同的回波数、FA、BW与FOV参数条件下,相位值的变化缺乏特异性。当浓度≥0.001 mmol/L时,回波数越小,对比度信噪比(contrast to noise ratio,CNR)越大(P<0.05);当Fe2+浓度≤0.01 mmol/L时,CNR随FA的变化差异没有统计学意义(P>0.05);当浓度≥0.001 mmol/L时,宽BW时,CNR值较大(P<0.05),而CNR随FOV的变化差异没有统计学意义(P>0.05)。      结论      ESWAN序列不同参数对成像特点的影响各不相同,回波数、BW对图像质量影响较大。
Abstract:
Objective      To determine the effect of different parameter setting in enhanced gradient echo T2 star weighted angiography (ESWAN) sequence on paramagnetic ion (Fe2+)’s imaging at different concentrations in vitro.       Methods      A model of FeSO4 solution at different concentrations was established. The samples were scanned repeatedly using different numbers of echo time, flip angle (FA), bandwidth (BW) and field of view (FOV) on the ESWAN sequence for signal changes. Relationship between imaging results and different parameters was analyzed by measuring phase values of interested areas in the images at different layers.       Results      ESWAN displayed slightly high signal of Fe2+. When Fe2+’s concentration was no more than 0.01 mmol/L, phase value was increased with the increase of concentrations. When Fe2+’s concentration was 0.1 mmol/L, artifacts were increased while phase value was decreased. There was no a certain rule in change of phase values under different conditions of number of echo time, FA, BW, and FOV. When Fe2+’s concentration was higher than 0.001 mmol/L, the number of echo time was smaller, and the contrast to noise ratio (CNR) was greater (P<0.05). When Fe2+’s concentration was lesser than 0.01 mmol/L, CNR had no statistically significant difference at different FAs (P>0.05). When Fe2+’s concentration was higher than 0.001 mmol/L, the CNR value was greater with wider BW (P<0.05), while the CNR difference between different FOVs was not statistically significant (P>0.05).       Conclusion      The imaging features are various from different ESWAN sequence parameters, and the number of echo time and bandwidth impact most on the image quality.

参考文献/References:

勒都晓兰, 吕发金, 陈莉, 等. ESWAN序列参数对不同浓度FeSO4溶液成像效果的研究[J].第三军医大学学报,2012,34(18):1901-1904.

相似文献/References:

[1]唐颖,朱悫,刘映江,等.磁共振引导高强度聚焦超声消融犬肾上腺的可行性研究[J].第三军医大学学报,2012,34(16):1621.
 Tang Ying,Zhu Que,Liu Yingjiang,et al.Experimental study on MRI-guided high-intensity focused ultrasound ablation of adrenal glands in dogs[J].J Third Mil Med Univ,2012,34(18):1621.
[2]勒都晓兰,吕发金,陈莉,等.ESWAN序列对脑梗死脑内微出血的诊断价值[J].第三军医大学学报,2012,34(19):1998.
 Ledu Xiaolan,Lu Fajin,Chen Li,et al.Value of enhanced gradient echo T2*-weighted angiography sequence for diagnosis of cerebral infarction accompanying cerebral microbleeds[J].J Third Mil Med Univ,2012,34(18):1998.
[3]邱明国,王健,谢兵,等.磁共振扩散张量成像在颅脑疾病的初步应用[J].第三军医大学学报,2005,27(23):2379.
[4]林亚南,程敬亮,张勇,等.大脑凸面小型脑膜瘤瘤周水肿的MRI表现与其病理亚型的关系[J].第三军医大学学报,2013,35(04):347.
 Lin Yanan,Cheng Jingliang,Zhang Yong,et al.MRI findings of peritumoral edema in convex surface small meningioma and its pathological subtypes[J].J Third Mil Med Univ,2013,35(18):347.
[5]龚明福,杨华,邹利光,等.包被材料对磁性纳米粒胶束MRI信号和弛豫效能的影响[J].第三军医大学学报,2013,35(01):5.
 Gong Mingfu,Yang Hua,Zou Liguang,et al.Effect of coating materials on MRI signal intensity and relaxivity of magnetic nanoparticles micelles[J].J Third Mil Med Univ,2013,35(18):5.
[6]陈蓉,张伟国,张连阳,等.MRI评价乳腺癌行保乳术的可行性研究[J].第三军医大学学报,2007,29(17):1712.
 CHEN Rong,ZHANG Wei-guo,ZHANG Lian-yang,et al.Feasibility of utilizing MRI for assessing breast-conserving surgery of breast cancer[J].J Third Mil Med Univ,2007,29(18):1712.
[7]秦勇,蔡金华,郑鹤琳,等.磁共振报告基因magA的慢病毒载体质粒构建及体外表达[J].第三军医大学学报,2011,33(13):1346.
 Qin Yong,Cai Jinhua,Zheng Helin,et al.Construction of recombinant lentivirus expression vector carrying MagA and its in vitro expression[J].J Third Mil Med Univ,2011,33(18):1346.
[8]李毅,肖顺武,张学军,等.颅内原发性黑色素瘤诊治体会[J].第三军医大学学报,2008,30(06):551.
[9]张园园,赵建农,郭大静,等.MRI动态增强扫描评估HIFU治疗原发性肝癌的疗效[J].第三军医大学学报,2008,30(08):754.
 ZHANG Yuan-yuan,ZHAO Jian-nong,GUO Da-jing,et al.Evaluation of HIFU effect on hepatocellular carcinoma with dynamic contrast enhanced MRI[J].J Third Mil Med Univ,2008,30(18):754.
[10]金旭红,杨柳,段小军,等.体外纳米磁标记骨髓间充质干细胞生物学特性及其MR成像[J].第三军医大学学报,2008,30(04):275.
 JIN Xu-hong,YANG Liu,DUAN Xiao-jun,et al.Biological characteristics and in vitro MRI of superparamagnetic ironoxide labeled bonederived mesenchymal stem cells from rabbits[J].J Third Mil Med Univ,2008,30(18):275.

更新日期/Last Update: 2012-09-18