文章信息/Info

Title:
Biomechanical testing and evaluation of a self-made allograft interbody fusion cage at lumbar spine
作者:
相子民应大君吴雪晖许建中陈卫军
第三军医大学:基础医学部人体解剖学教研室,重庆市生物力学实验室,西南医院骨科,全军矫形外科中心
Author(s):
XIANG Zi-min YING Da-jun WU Xue-hui XU Jian-zhong CHEN Wei-jun
Department of Anatomy, College of Medicine, Department of Orthopaedics, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
关键词:
异体骨椎间融合器腰椎生物力学测评
Keywords:
allograft interbody fusion cage lumbar spine biomechanics testing and evaluation
分类号:
R197.39;R318.01;R322.71
文献标志码:
A
摘要:
目的    评价植入自制异体骨腰椎间融合器(异体骨cage)的腰椎节段的稳定性和生物力学性能。    方法    将自制异体骨腰椎间融合器植入5具新鲜青壮年尸体标本的L4~L5椎间隙,进行抗弯、抗扭转和抗压缩测试,并与植入前和髓核切除后进行比较。    结果    自制异体骨腰椎间融合器植入后,腰椎节段的屈曲和后伸的抗弯强度显著增加(P<0.01),抗扭转强度也有较显著增加(P<0.05)。其压缩刚度比髓核摘除后高(P<0.05) 。    结论    自制异体骨腰椎间融合器植入腰椎节段的稳定性提高。自制异体骨腰椎间融合器具有足够的支撑、维持或增加椎间隙高度的功能,椎间稳定性好,其设计符合椎间隙解剖学特点,可以达到生物力学和临床应用要求,但目前临床应用时仍需加用内固定。
Abstract:
Objective    To evaluate the stability and compressive mechanical functions of the lumbar spine following insertion of a new self-made allograft interbody fusion cage.     Methods    Anti-bending intensity with three points test, anti-rotation intensity and compressive stiffness were measured at L4-L5 lumbar spine on five adult human fresh cadaveric specimens following insertion of a new self-made allograft interbody fusion cage and compared with that of before and after nucleus pulposus removal.     Results    The anti-bending intensity of flexion and extension of lumbar spine after inserting a new allograft interbody fusion cage was increased significantly (P<0.01), and so did the anti-rotation intensity (P<0.05). The test also revealed that the compressive stiffness after inserting a new allograft interbody fusion cage increased significantly as compared with that of nucleus pulposus removal (P<0.05).      Conclusion    The new self-made allograft interbody fusion cage can sustain or increase the height of intervertebral space of the lumbar spine, provide enough support and improve the stability of the lumbar spine. Its design is distinctive and reasonable. It completely meets biomechanical and clinical requirements.

参考文献/References:

相子民,应大君,吴雪晖,等. 自制异体骨腰椎间融合器的力学测评[J]. 第三军医大学学报, 2007, 29(12):1237-1239.

相似文献/References:

[1]郑琦,应小樟,石仕元,等.复杂性腰椎管狭窄症的有限元建模与分析[J].第三军医大学学报,2012,34(18):1897.
 Zheng Qi,Ying Xiaozhang,Shi Shiyuan,et al.Finite element modeling and analysis of complicated lumbar spinal stenosis[J].J Third Mil Med Univ,2012,34(12):1897.
[2]戴书华,邹利光,廖翠薇,等.腰椎椎体后缘软骨结节的影像学诊断[J].第三军医大学学报,2006,28(01):24.
[3]王群波,蒋电明,李智,等.纳米羟基磷灰石/聚酰胺66复合人工椎体治疗胸腰椎椎体肿瘤的效果[J].第三军医大学学报,2006,28(03):263.
[4]罗刚,李长青,腾海军,等.单节段腰椎小关节分级切除对腰椎稳定性影响的生物力学研究[J].第三军医大学学报,2005,27(18):1871.
[5]王洪伟,周跃,李长青,等.附加经伤椎椎弓根螺钉内固定治疗胸、腰椎骨折的临床评价[J].第三军医大学学报,2010,32(04):376.
 Wang Hongwei,Zhou Yue,Li Changqing,et al.Internal fixation of thoracolumbar spine fractures with screws through the pedical of fractured vertebral arch[J].J Third Mil Med Univ,2010,32(12):376.
[6]李长青,罗刚,周跃,等.微创三节段经皮椎弓根螺钉内固定选择性治疗胸腰椎骨折[J].第三军医大学学报,2009,31(22):2284.
 LI Chang-qing,LUO Gang,ZHOU Yue,et al.Application of mini-invasive percutaneous pedicle screw fixation in thoracolumbar fracture using multi-level Sextant system[J].J Third Mil Med Univ,2009,31(12):2284.
[7]时伟峰,郭从涛,周强.异体腓骨环状腰椎间融合器的生物力学研究[J].第三军医大学学报,2013,35(12):1279.
 Shi Weifeng,Guo Congtao,Zhou Qiang.Biomechanical study of allogeneic fibula ring lumbar interbody fusion cage[J].J Third Mil Med Univ,2013,35(12):1279.
[8]王明贵,周跃,初同伟.腰椎间盘突出症手术疗效的临床观察[J].第三军医大学学报,2005,27(05):436.
[9]谢新立,程兵,杜晓光,等.“倒八字征”:第5腰椎关节突关节退行性变骨显像典型表现研究[J].第三军医大学学报,2011,33(13):1422.
[10]刘桂勇,胡永军,范远俊,等.椎体内植骨治疗胸腰椎爆裂性骨折[J].第三军医大学学报,2015,37(06):584.

更新日期/Last Update: 2008-10-23